Tesis

Akurasi Uji Short Physical Performance Battery sebagai Tes Performa Fisik dalam Penegakan Diagnosa Sarkopenia pada Pasien Lanjut Usia Rawat Jalan = Accuracy Test of Short Physical Performance Battery as a Physical Performance Test in Sarcopenia Diagnosis on Outpatient Geriatry.

Tesis ini bertujuan untuk mengetahui nilai titik potong tes SPPB sebagai tes performa fisik dalam mendiagnosa sarkopenia pada pasien lanjut usia di rawat jalan. Selain itu juga untuk mengetahui nilai sensitivitas dan spesifisitas tes SPPB berdasarkan kecepatan jalan 6 meter untuk estimasi performa fisik sebagai komponen sarkopenia. Penelitian ini merupakan studi potong lintang pada pasien lanjut usia rawat jalan di RSUPN Ciptomangunkusumo. Pada penelitian ini didapatkan 100 subjek yang diminta melakukan uji SPPB, uji kecepatan jalan 6 meter, uji penilaian massa otot dengan BIA (Bio Impedance Analysis), dan penilaian kekuatan otot dengan menggunakan handgrip dynamometer. Dari hasil penilaian didapatkan nilai titik potong 7 untuk populasi total dan populasi perempuan. Sedangkan untuk populasi laki laki didapatakan nilai 8. Setelah didapatkan titik potong baru, dilakukan uji diagnostik antara nilai SPPB titik potong baru dengan status performa fisik menurun berdasarkan kecepatan jalan 6 meter. Dari penilaian didapatkan sensitivitas 81.5% dan spesifisitas 73.7% untuk populasi total. Pada populasi perempuan didapatkan sensitivitas 81.4% dan spesifisitas 66.7%. Sedangkan untuk populasi laki laki menggunakan titik potong 8 didapatkan sensitivitas 81.8% dan spesifisitas 71.4%. Kesimpulan penelitian ini adalah SPPB dengan nilai titik potong 7 untuk populasi perempuan dan 8 untuk populasi laki laki baik dipakai sebagai alat uji untuk screening dan diagnostik performa fisik sebagai komponen sarkopenia rawat jalan.
Kata kunci: sarkopenia, SPPB, performa fisik, kecepatan jalan, geriatric.


This thesis aims to determine the cut-off point of the SPPB test as a physical performance test in diagnosing sarcopenia in elderly patients on an outpatient basis. In addition, to determine the sensitivity and specificity of the SPPB test based on a walking speed of 6 meters to estimate physical performance as a component of sarcopenia. This study is a cross-sectional study of elderly outpatients at Ciptomangunkusumo General Hospital. In this study, 100 subjects were asked to perform the SPPB test, 6 meter walking speed test, muscle mass assessment test using BIA (Bio Impedance Analysis), and muscle strength assessment using a handgrip dynamometer. From the results of the assessment, it was found that the cut-off point was 7 for the total population and the female population. As for the male population, a score of cut oof point is 8. After obtaining a new cut-off point, a diagnostic test was conducted between the SPPB value of the new cut-off point and the decreased physical performance status based on a 6-metre walking speed. From the assessment, sensitivity was 81.5% and specificity was 73.7% for the total population. In the female population, sensitivity was 81.4% and specificity was 66.7%. Meanwhile, for the male population using the 8 cut-off point, the sensitivity was 81.8% and the specificity was 71.4%.The conclusion of this study is that the SPPB with a cutoff value of 7 for the female population and 8 for the male population can be used as a test tool for screening and diagnostic of physical performance as a component of outpatient sarcopenia Key words: Sarcopenia, SPPB, physical performance, walking speed, geriatrics
Key words: Sarcopenia, SPPB, physical performance, walking speed, geriatrics

Judul Seri
-
Tahun Terbit
2021
Pengarang

Tiffany - Nama Orang
Aria Kekalih - Nama Orang
Fitri Anestherita - Nama Orang
Wanarani Alwin - Nama Orang

No. Panggil
T21493fk
Penerbit
Jakarta : Program Studi Kedokteran Fisik dan Rehabilitasi.,
Deskripsi Fisik
xviii, 86 hal; ill; 21 x 30 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
NONE
Edisi
-
Subjek
Info Detail Spesifik
Tanpa Hardcopy
T21493fkT21493fkPerpustakaan FKUITersedia
Image of Akurasi Uji Short Physical Performance Battery sebagai Tes Performa Fisik dalam Penegakan Diagnosa Sarkopenia pada Pasien Lanjut Usia Rawat Jalan = Accuracy Test of Short Physical Performance Battery as a Physical Performance Test in Sarcopenia Diagnosis on Outpatient Geriatry.

Related Collection