Tesis
Penggunaan Analisis Hitung Piksel Dalam Penilaian Efek Vasokonstriksi Fenilefrin 2,5% Pada Pembuluh Darah Konjungtiva Pasien Pre-Operasi Strabismus = The Use of Pixel Count Analysis in Evaluating Vasoconstriction Effect of 2.5% Phenylephrine on Conjunctival Vessels of Pre-Operative Strabismus Patients.
Penelitian ini menilai validitas dan keandalan / reliability dari analisis hitung piksel untuk penilaian vasokonstriksi pembuluh darah konjungtiva dengan pemberian tetes mata fenilefrin 2,5%. Penelitian ini merupakan studi prospektif analitik berpasangan. Sebanyak 15 subjek dengan kriteria strabismus horizontal murni usia 5 - 35 tahun yang membutuhkan operasi koreksi strabismus dilibatkan pada penelitian ini. Pengambilan data dilakukan melalui foto konjungtiva yang kemudian diolah dan dianalisis menggunakan aplikasi FIJI. Foto dirubah menjadi bentuk binari menggunakan plugin semi-otomatis vessel analysis pada aplikasi FIJI. Modifikasi foto menjadi bentuk binari dapat membuat pembuluh darah dinilai berdasarkan hitung piksel. Pada penelitian ini, analisis hitung piksel dapat mendeteksi perubahan jumlah piksel pasca penetesan fenilefrin 2,5% yang bermakna secara statistik, sehingga bisa disimpulkan sebagai alat yang valid untuk menilai vasokonstriksi pembuluh darah konjungtiva. Keandalan dinilai menggunakan Intraclass Correlation Coefficient, dimana teknik ini didapatkan hasil yang bervariasi, namun nilai keandalan masih dapat ditingkatkan. Penelitian ini juga menilai efek fenilefrin 2,5% pada parameter kardiovaskular, namun tidak didapatkan korelasi yang signifikan.
Kata kunci: Analisis hitung piksel, vasokonstriksi, conjunctiva vessels, strabismus
This study assessed the validity and reliability of pixel count analysis for evaluating vasoconstriction of conjunctival vessels by administering 2.5% phenylephrine eye drops. This study was a paired analytic prospective study. A total of 15 subjects with horizontal strabismus, aged 5 - 35 years, whose requiring strabismus correction surgery were included in this study. Data retrieval was done through conjunctival photos which then processed and analysed using the FIJI application. Photos were converted into binary forms using a semi-automatic plugin called “vessel analysis” in the FIJI application. Transforming blood vessel into binary forms would allow analysis using pixel count. In this study, pixel count analysis can detect changes in the number of pixels after 2.5% phenylephrine administration and were statistically significant, so that it can be concluded that pixel count analysis as a valid tool for assessing conjunctival blood vessel vasoconstriction. The reliability was analysed using Intraclass Correlation Coefficient and the value was obtained varied but can still be improved. This study also evaluate the cardiovascular effect of 2,5% phenylephrine, yet no significant correlation was found.
Keywords: pixel count analysis, vasoconstriction, conjunctiva vessels, strabismus
- Judul Seri
-
-
- Tahun Terbit
-
2019
- Pengarang
-
Anissa Nindhyatriayu Witjaksono - Nama Orang
Gusti Gede Suardana - Nama Orang
Anna Puspitasari Bani - Nama Orang
Virna Dwi Oktariana - Nama Orang
Aria Kekalih - Nama Orang - No. Panggil
-
T19303fk
- Penerbit
- Jakarta : Program Studi Ilmu Kesehatan Mata., 2019
- Deskripsi Fisik
-
xv, 76 hal; ill; 21 x 30 cm
- Bahasa
-
Indonesia
- ISBN/ISSN
-
-
- Klasifikasi
-
T19303fk
- Edisi
-
-
- Subjek
- Info Detail Spesifik
-
-
T19303fk | T19303fk | Perpustakaan FKUI | Tersedia |
Masuk ke area anggota untuk memberikan review tentang koleksi