Perbandingan tekanan balon pipa endotrakeal terhadap perubahan posisi kepala dan tubuh : analisis terhadap rotasi kepala dan lateral dekubitus = Comparison of endotracheal cuff pressure based on head and neck position: analysis of head rotation and lateral decubitus.

Intubasi endotrakeal merupakan upaya menjaga jalan nafas dan memberikan ventilasi. Intubasi endotrakeal menggunakan pipa endotrakeal yang memiliki balon dan dapat dikembangkan dengan tekanan yang direkomendasikan adalah 20-30 cmH2O. Terdapat berbagai faktor yang dapat mempengaruhi tekanan balon pipa endotrakeal, salah satunya rotasi kepala dan perubahan posisi tubuh. Penelitian ini bertujuan untuk mengetahui perbedaan tekanan balon pipa endotrakeal terhadap perubahan posisi rotasi kepala 15 o o o , 45 , 60 , serta perubahan posisi lateral dekubitus. Penelitian dilakukan pada pasien yang menjalani anestesia umum dan terintubasi di RSUPN Dr. Cipto Mangunkusumo. Tekanan awal balon ditetapkan sebesar 25 cmH2O lalu dilakukan perubahan posisi dari supinasi ke lateral dekubitus, rotasi kepala 15°, 45°, dan 60° lalu dilakukan penilaian oleh penilai yang berbeda. Hasil penelitian menunjukkan terdapat perbedaan bermakna antara tekanan balon pipa endotrakeal pada posisi supinasi dengan posisi rotasi kepala 15 o , o o 45 , 60 dan lateral dekubitus dengan nilai uji Friedman p < 0,001 serta uji post-hoc dengan nilai uji Wilcoxon masing-masing p < 0,001. Walaupun terdapat perbedaan bermakna secara statistik, namun hanya posisi lateral dekubitus yang memiliki perbedaan bermakna secara klinis. Kesimpulan penelitian ini adalah terdapat perbedaan bermakna secara statistik pada perubahan posisi rotasi kepala 15 o o , 45 , o 60 dan lateral dekubitus dan hanya posisi lateral dekubitus yang memiliki perbedaan tekanan bermakna secara klinis.
Kata kunci: Intubasi endotrakeal, tekanan balon pipa endotrakeal, rotasi kepala, lateral dekubitus


Endotracheal intubation is an effort to maintain airway and deliver ventilation. It uses endotracheal tube which has inflatable cuff with recommended pressure of 2030 cmH2O. There are various factors affecting the endotracheal tube cuff pressure, including head rotation and change of body position. This study aims to investigate the effect of 15o , 45 0 , 60 0 head rotation and lateral decubitus body position to endotracheal tube cuff pressure. This study was conducted to intubated patients undergoing general anesthesia in RSUPN Dr. Cipto Mangunkusumo. Initial cuff pressure was set to 25 cmH2O; then body position was altered from supine to lateral decubitus; head rotated to 15°, 45°, 60°. Cuff pressure was measured by different observers. Results show significant difference in endotracheal tube cuff pressure between supine, head rotations, and lateral decubitus positions, with p < 0,001 and subsequent post-hoc analysis yielding to p < 0,001. Even though statistically significant, only lateral decubitus position yields to clinically significant pressure difference.
Keywords: Endotracehal intubation, cuff pressure, head rotation, lateral decubitus.

Judul Seri
-
Tahun Terbit
2019
Pengarang

Kustenti Prima - Nama Orang
Ratna Farida Soenarto - Nama Orang
Eddy Harijanto - Nama Orang

No. Panggil
T19100fk
Penerbit
Jakarta : Program Studi Anestesiologi dan Terapi Intensif.,
Deskripsi Fisik
xvii, 63 hal; ill; 21 x 30 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
T19100fk
Edisi
-
Subjek
Info Detail Spesifik
-
T19100fkT19100fkPerpustakaan FKUITersedia
Image of Perbandingan tekanan balon pipa endotrakeal terhadap perubahan posisi kepala dan tubuh : analisis terhadap rotasi kepala dan lateral dekubitus = Comparison of endotracheal cuff pressure based on head and neck position: analysis of head rotation and lateral decubitus.

Related Collection