Tesis

Nilai Normal Pemeriksaan Ambang Penghidu dengan Uji Penghidu Intravena Pada Subjek Dewasa Tanpa Gangguan Penghidu di RSUPN Cipto Mangunkusumo = Normative Value of Olfactory Threshold Using Intravenous Olfaction Test in Adult Subjects With Normal Olfactory Function in Cipto Mangunkusumo Hospital .

Latar Belakang Diagnosis gangguan penghidu memerlukan pemeriksaan yang akurat. Saat ini Departemen THT-KL RSUPN Cipto Mangunkusumo menggunakan Sniffin’ Sticks sebagai pemeriksaan rutin. Uji penghidu intravena (UPI) merupakan pemeriksaan penghidu sederhana yang dapat melengkapi pemeriksaan Sniffin’ Sticks karena dapat digunakan untuk menilai jalur retronasal dan prognosis. Tujuan Mengetahui sebaran nilai normal ambang penghidu berdasarkan UPI pada subjek dewasa tanpa gangguan penghidu. Metode Penelitian ini merupakan penelitian potong lintang bersifat deskriptif yang dilakukan di Unit Rawat Jalan Terpadu THT-KL RSUPN Cipto Mangunkusumo periode Januari-Februari 2016 dengan melibatkan 55 subjek. Uji penghidu intravena dikerjakan pada subjek yang telah terbukti normosmia berdasarkan pemeriksaan Sniffin’ Sticks. Hasil Rerata nilai normal ambang berdasarkan UPI adalah 16,29±5,52 detik dengan persentil 5 pada 9,46 detik dan persentil 90 pada 22,99 detik. Nilai tengah durasi penghidu yaitu 100,95 detik dengan persentil 5 pada 32,21 detik dan persentil 90 pada 177,24 detik. Tidak terdapat korelasi antara hasil pemeriksaan penghidu berdasarkan UPI dan Sniffin’ Sticks. Kesimpulan Uji penghidu intravena dapat diaplikasikan dalam evaluasi gangguan penghidu sebagai pelengkap Sniffin’ Sticks di Departemen THT-KL RSUPN Cipto Mangunkusumo. Penelitian lebih lanjut diperlukan untuk menganalisis peranan UPI sebagai alat diagnosis dan kemampuannya menilai prognosis.
Kata kunci: fungsi penghidu, pemeriksaan penghidu kemosensori, uji penghidu intravena, Sniffin’ Sticks



Background The diagnosis of olfactory loss needs accurate examinations. At this moment, the Department of Otolaryngology Head and Neck Surgery (ORL-HNS) has used Sniffin’ Sticks as a routine examination. Intravenous olfaction test (IOT) is a simple examination to complement the Sniffin’ Sticks examination due to its ability to evaluate retronasal pathway and prognosis. Objective To investigate the normal value of olfactory threshold using the IOT in adult subjects without olfactory loss. Methods This research is a cross sectional, descriptive study took place at ORL-HNS Outpatient Clinic of Cipto Mangunkusumo Hospital included 55 subjects in January-February 2016. Intravenous olfactory examination was performed in normosmia subjects based on Sniffin’ Sticks examination. Results Normative value of olfactory threshold using IOT was 16,29±5,52 seconds (mean ± SD) with the 5th percentile on 9,46 seconds and 90th percentile on 22,99 seconds. The duration was 100,95 seconds with the 5th percentile on 32,21 seconds and 90th percentile on 177,24 seconds. There was no correlation between the olfactory function results based on IOT and Sniffin’ Sticks. Conclusion Intravenous olfactory test is applicable for the evaluation of olfactory function, complementing the Sniffin’ Sticks examination in ORL-HNS Outpatient Clinic of Cipto Mangunkusumo Hospital. Further research is needed to investigate the role of IOT as a diagnostic tool and its feature to evaluate prognostic.
Keywords:olfactory function, chemosensoric olfactory examination, intravenous olfaction test (IOT), Sniffin’ Sticks

Judul Seri
-
Tahun Terbit
2016
Pengarang

Tissa Indriaty - Nama Orang
Retno S Wardani - Nama Orang
Niken Lestari - Nama Orang
Saptawati Bardosono - Nama Orang

No. Panggil
T 16 203 FK
Penerbit
Jakarta : Program Studi Ilmu Kesehatan Telinga Hidung Tenggorok.,
Deskripsi Fisik
xxii, 97 hlm., 21 cm x 30 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
NONE
Edisi
-
Subjek
Info Detail Spesifik
-
T16203FKT16203FKPerpustakaan FKUITersedia
Image of Nilai Normal Pemeriksaan Ambang Penghidu dengan Uji Penghidu Intravena Pada Subjek Dewasa Tanpa Gangguan Penghidu di RSUPN Cipto Mangunkusumo = Normative Value of Olfactory Threshold Using Intravenous Olfaction Test in Adult Subjects With Normal Olfactory Function in Cipto Mangunkusumo Hospital .

Related Collection