Tesis

Perbandingan Efektivitas Dan Keamanan Nukleofraksis 4 Segmen Terhadap 6 Segmen Pada Fakoemulsifikasi Katarak Derajat Sedang Keras = Comparison of Effectiveness And Safety of 4 Segments and 6 Segments Nucleofractis in Stop and Chop Technique for Moderate-Hard Cataract.

Tujuan: untuk mengetahui perbandingan efektivitas, dinilai dari cumulative dissipated energy (CDE), phaco time, tajam penglihatan dengan koreksi (TPDK)) dan keamanan, dinilai dari endothelial cell density (ECD), central corneal thickness (CCT), dan volume balanced salt solution (BSS)), antara nukleofraksis empat segmen terhadap enam segmen dengan teknik stop and chop pada fakoemulsifikasi katarak derajat sedang-keras. Metode: Uji klinis prospektif yang melibatkan 42 dengan densitas nuklear derajat NO/NC 3-5 berdasarkan Lens Opacities Classification System III (LOCS III), dirandomisasi menjadi dua kelompok nukleofraksis, empat segmen (21 subjek) atau enam segmen (21 subjek). Pengukuran objektif dilakukan pre operatif, 1 hari, 1 minggu, dan 1 bulan pasca operasi yang meliputi ECD, CCT, dan TPDK. Intraoperatif dinilai CDE, phaco time, dan volume BSS yang terpakai. Hasil: terjadi penurunan ECD (5.76 ± 29.08 µm VS 2.33 ± 13.73 µm) dan peningkatan CCT (346.42 ± 154.45 sel/mm 2 VS 247.05 ± 160.40 sel/mm ) pada kedua kelompok pada satu bulan pasca operasi. Tidak ada perbedaan yang bermakna pada TPDK satu bulan pasca operasi kedua kelompok (logMAR 0.05 VS 0.04). Parameter intra-operatif dalam kelompok empat segmen (CDE 20.73 ± 6.46, phaco time 78.49 ± 23.63 detik, BSS 59.38 ± 12.04 ml) sebanding dengan kelompok enam segmen (CDE 20.46 ± 5.47, phaco time 78.62 ± 13.80 detik, BSS 58.86 ± 13.32 ml), dan tidak ada perbedaan yang bermakna secara statistik. Simpulan: tidak terdapat perbedaan yang bermakna secara statistik parameter efektivitas dan keamanan antara kelompok nukleofraksis empat segmen dan enam segmen. Namun, pasca operasi nukleofraksis empat segmen mempunyai kecenderungan menimbulkan efek kerusakan endotel lebih banyak dibandingkan nukleofraksis enam segmen.
Kata kunci: fakoemulsifikasi, katarak derajat sedang-keras, nukleofraksis, teknik stop and chop


Objective: to compare effectiveness, assessed by cumulative dissipated energy (CDE), phaco time, best corrected visual acuity (BCVA), and safety which were observed by endothelial cell density (ECD), central corneal thickness (CCT), and balanced salt solution (BSS) volume used, of four and six segments nucleofractis in stop and chop phacoemulsification technique for moderate-hard cataract. Methods: This prospective study comprised forty-two subjects with NO/NC 3-5 nuclear density according to the Lens Opacities Classification System III (LOCS III) system. Patients were equally randomized into four segments or six segments nucleofractis group. Stop-and-chop technique were applied in all subjects. The objective measurements of ECD, CCT, and BCVA were performed pre-operative, 1 day, 1 week, and 1 month post-operative. Phaco time, CDE and BSS volume were measured intraoperatively. Results: The mean ECD were reduced (5.76 ± 29.08 µm VS 2.33 ± 13.73 µm) and CCT increased (346.42 ± 154.45 cells/mm2 VS 247.05 ± 160.40 cells/mm in both groups after 1 month follow-up. No statistically difference was found between mean BCVA at 1 month follow-up in both group (logMAR 0.05 VS 0.04). All intraoperative parameters of four segments group (CDE 20.73 ± 6.46, phaco time 78.49 ± 23.63 second, BSS 59.38 ± 12.04 ml) were comparable with six segments group (CDE 20.46 ± 5.47, phaco time 78.62 ± 13.80 second, BSS 58.86 ± 13.32 ml). Conclusions: No effectiveness and safety difference between four and six segments nucleofractic in stop and chop phacoemulsification technique for moderate – hard cataract. However, our study demonstrates the tendency of higher endothelial cell loss in four segments nucleofractis.
Keywords: moderate-hard cataract, nucleofractis, phacoemulsification, stop and chop technique.

Judul Seri
-
Tahun Terbit
2015
Pengarang

Azrina Noor - Nama Orang
Bondan Harmani - Nama Orang
Amir Shidik - Nama Orang
Joedo Prihartono - Nama Orang

No. Panggil
T 15 160 FK
Penerbit
Jakarta : Program Studi Ilmu Kesehatan Mata.,
Deskripsi Fisik
xi, 64 hlm.; 20 x 29 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
NONE
Edisi
-
Subjek
Info Detail Spesifik
-
T15160FKT15160FKPerpustakaan FKUITersedia
Image of Perbandingan Efektivitas Dan Keamanan Nukleofraksis 4 Segmen Terhadap 6 Segmen Pada Fakoemulsifikasi Katarak Derajat Sedang Keras = Comparison of Effectiveness And Safety of 4 Segments and 6 Segments Nucleofractis in Stop and Chop Technique for Moderate-Hard Cataract.

Related Collection