Tesis
Korelasi Nilai Fungsi Sistolik Ventrikel Kiri antara Echocardiography 2Ddengan Dual Source Computed Tomography(DSCT) Jantung pada Pasien Penyakit Jantung Koroner Stabil diRSUPN Cipto Mangunkusumo = Correlation of left ventriculer systolic function value between Echocardiography 2D andcardiac Dual Source Computed Tomography(DSCT) in stable coronary heart disease at Cipto Mangunkusumo hospital.
Latar belakang dan tujuan: Menentukan korelasi nilai Ejection Fraction (EF)
ventrikel kiri pada echo 2D dan DSCT jantung pada pasien Penyakit Jantung
Koroner (PJK) stabil di RSUPN Cipto Mangunkusumo, sehingga nilai EF
ventrikel kiri DSCT jantung dapat dijadikan acuan untuk evaluasi,
penatalaksanaan dan prognosis pada PJK stabil yang mempunyai indikasi
dilakukan CT jantung.
Metode: Analisa retrospektif dari 30 pasien PJK stabil yang menjalani
pemeriksaan echo 2D dan DSCT jantung dengan jarak waktu ≤ 3 bulan, meliputi
penilaian EF ventrikel kiri. Berdasarkan nomor rekam medis yang ada, dilakukan
pengambilan data EF ventrikel kiri echo 2D serta data tambahan lainnya. Nilai EF
ventrikel kiri secara DSCT di evaluasi kembali pada cardiac workstation
(Siemens, Leonardo), kemudian ditentukan bagaimana korelasinya dengan nilai
EF ventrikel kiri secara echo 2D. Analisis statistik penelitian ini menggunakan uji
Spearman
Hasil: Terdapat perbedaan nilai EF ventrikel kiri sebanyak 4% antara echo 2D
dengan DSCT jantung. Perbedaan sebanyak 4% ini tidak bermakna signifikan
secara klinis namun bermakna secara statistik. Nilai R Spearman yang didapat
adalah 0,17 sementara nilai p 0,364 (p > 0,005), artinya tidak terdapat korelasi
antara nilai EF ventrikel kiri secara echo 2D dengan DSCT jantung pada pasien
PJK stabil yang menjalani pemeriksaan echo 2D dan DSCT jantung dengan jarak
≤ 3 bulan di RSUPN Cipto Mangunkusumo.
Kesimpulan: Walaupun pada penelitian ini secara statistik tidak berkorelasi,
namun pada keadaan hasil echo yang borderlineatau pada pasien PJK stabil yang
mempunyai indikasi dilakukan CT jantung, nilai EF ventrikel kiri pada CT dapat
menjadi acuan untuk penatalaksanaan selanjutnya.
Kata kunci :Echocardiography 2D;Ejection Fraction;DSCT jantung
Background and Objectives: to determine the correlation left ventricle Ejection
Fraction (EF) between echo 2D and cardiac DSCT in Coronary Heart Disease
(CHD) patients at Cipto Mangunkusumo Hospital, so that the value of the left
ventricular EF cardiac DSCT can be used as a reference for the evaluation,
treatment and prognosis in stable CHD who have an indication of cardiac CT.
Methods: A retrospective analysis of 30 patients with stable CHD who underwent
2D echo and cardiac DSCT with interval ≤ 3 months, include assessment of left
ventricular EF. Based on the existing medical record number, performed data
collection left ventricular EF 2D echo and other additional data. Value of left
ventricular EF in DSCT in return on cardiac evaluation workstation (Siemens,
Leonardo), then determined how its correlation with left ventricular EF values in
2D echo. Statistical analysis of this study using the Spearman test.
Result: There are differences in left ventricular EF value by 4% between 2D echo
with cardiac DSCT. The difference of 4% is not clinically significant, but
statistically significant. Spearman R value obtained was 0.17 while the p-value
0.364 (p> 0.005), meaning that there is no correlation between the value of the left
ventricular EF in 2D echo and cardiac DSCT in patients with stable CHD who
underwent 2D echo and cardiac DSCT with distance ≤ 3 month in Cipto
Mangunkusumo hospital.
Conclusion: Although this study was not statistically correlated, but the results
echo borderline or in stable CHD patients who had cardiac CT indications, left
ventricular EF values on CT can be a reference for further management.
Keyword: Echocardiography 2D;Ejection Fraction;cardiac DSCT.
- Judul Seri
-
-
- Tahun Terbit
-
2014
- Pengarang
-
Sonya Anasrul - Nama Orang
Sally Aman Nasution - Nama Orang
Indrati Suroyo - Nama Orang - No. Panggil
-
T14520fk
- Penerbit
- Jakarta : Program Studi Ilmu Radiologi., 2014
- Deskripsi Fisik
-
xiv, 60 hlm, 21 x 29 cm
- Bahasa
-
Indonesia
- ISBN/ISSN
-
-
- Klasifikasi
-
T14520fk
- Edisi
-
-
- Subjek
- Info Detail Spesifik
-
-
T14520fk | T14520fk | Perpustakaan FKUI | Tersedia |
Masuk ke area anggota untuk memberikan review tentang koleksi