Tesis

Uji validasi konstruksi dan reliabilitas instrumen The Amsterdam Preoperative Anxiety and Information Scale (APAIS) versi Indonesia = Construct Validity and Reliability of The Amsterdam Preoperative Anxiety and Information Scale (APAIS) Indonesian Version

Latar Belakang: Kecemasan praoperatif mempunyai pengaruh yang
signifikan terhadap pembiusan dan pembedahan. Saat ini belum ada instrumen
spesifik untuk mengukur kecemasan praoperasi pada populasi Indonesia.
Instrumen APAIS merupakan instrumen yang telah digunakan luas di dunia
untuk mengukur kecemasan praoperatif. Penerjemahan, validasi dan
reliabilitas instrumen APAIS pada populasi Indonesia merupakan tujuan
penelitian ini.
Metode: Penerjemahan APAIS dilakukan dengan penerjemahan maju dan
mundur. Sebanyak 102 pasien yang akan menjalani operasi elektif mengisi
instrumen APAIS versi Indonesia satu hari sebelumnya. Validitas konstruksi
dinilai dengan metode analisis faktor. Reliabilitas dinilai dengan konsistensi
internal Cronbach’s Alpha.
Hasil: Sebanyak 102 pasien (42 laki-laki dan 60 perempuan) menjadi subjek
penelitian penelitian ini. Analisis faktor dengan rotasi oblique menghasilkan
dua skala yaitu skala kecemasan dan kebutuhan informasi. Hasil reliabilitas
Cronbach’s Alpha skala kecemasan dan kebutuhan informasi APAIS versi
Indonesia cukup tinggi yaitu 0,825 dan 0,863. Pasien dengan kebutuhan
informasi tinggi menunjukkan kecemasan praoperatif yang lebih tinggi. Skala
APAIS tidak berhubungan dengan jenis kelamin, riwayat operasi, jenis operasi
atau jenis anestesi
Simpulan: APAIS versi Indonesia sahih (valid) dan handal (reliable) untuk
mengukur kecemasan praoperatif pada populasi Indonesia. Penelitian
selanjutnya diperlukan untuk menentukan sensitivitas dan spesifisitas cut off
point kecemasan pada populasi Indonesia
Kata Kunci: kecemasan praoperatif, APAIS, validitas konstruksi, reliabilitas


Background: Preoperative anxiety has a significant effect on anesthesia and
surgery. Currently there is no specific instrument for measuring preoperative
anxiety in Indonesian population. APAIS have been used worldwidely to
measure preoperative anxiety. Translation, validation and reliability of
instrument APAIS in Indonesian population is the purpose of this study.
Methods: The translation was done in forward and backward translation. Total
sample 102 patient undergoing elective surgery answered the Indonesian
APAIS one day before operation. Construct validity was determined by factor
analysis with oblique rotation. The internal consistency was evaluated by
Cronbach’s alpha.
Results: A total 102 patient (42 men and 60 women) enrolled in this study.
The two scales anxiety and need for information could be replicated by factor
analysis. High reliability Cronbach’s alpha anxiety and need for information
scale Indonesian APAIS respectively 0,825 and 0,863. Patient with high
information needs showed higher preoperative anxiety. The APAIS scale are
independent of sex, previous surgery, type of operation or type of anesthesia.
Conclusion: Indonesian APAIS proved to be reliable and valid instrument to
measure preoperative anxiety in Indonesian population. Further research is
needed to determine the sensitivity and specificity of Indonesian APAIS to get
cut off point anxiety of Indonesian population.
Keyword: Preoperative anxiety, APAIS, construct validation, reliability

Judul Seri
-
Tahun Terbit
2014
Pengarang

Muhammad Fikry Firdaus - Nama Orang
DEWI Wulandari - Nama Orang
Saptawati Bardosono - Nama Orang
Nina Irawati - Nama Orang
Niken Lestari - Nama Orang

No. Panggil
T14473fk
Penerbit
Jakarta : Program Studi Anestesiologi dan Terapi Intensif.,
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
T14473fk
Edisi
-
Subjek
Info Detail Spesifik
-
T14473fkT14473fkPerpustakaan FKUITersedia
Image of Uji validasi konstruksi dan reliabilitas instrumen The Amsterdam Preoperative Anxiety and Information Scale (APAIS) versi Indonesia = Construct Validity and Reliability of The Amsterdam Preoperative Anxiety and Information Scale (APAIS) Indonesian Version

Related Collection